Off-the-shelf & Custom Infrared Lens, thermal imaging cameras & systems components

Home / All / LWIR Lens | Infrared Optics / HD Lenses /

Fixed Athermalized Focus LWIR Lens 50mm f/1.2 HD

Home / All / LWIR Lens | Infrared Optics / HD Lenses /

Fixed Athermalized Focus LWIR Lens 50mm f/1.2 HD

Find Your Product
Whatever your requirements, our know-how, expert team, and technology are all there, ready to provide you with the precise, fully-tailored solution you need.
Please send your message to us
*Email
Name
Tel
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.

Fixed Athermalized Focus LWIR Lens 50mm f/1.2 HD

Fixed Athermalized Focus LWIR Lens 50mm f/1.2 HD
CategoriesHD Lenses
BrandQuanhom Optronics
ModelGLA5012KA
LWIR Lens50mm f/1.2
ApplicationsThermal imaging monocular/binoculars
Mechanical InterfaceThread
Update TimeNov 22,2024
Detail Information
  • Specifications
  • Download file
  • FAQ
  • Video
  • Applications
Specifications
HFOV
160x120
320x240
336x256
384x288
640x480
640x512
1024x768
1280x1024
25μm
4.6°
9.1°
9.6°
11.0°
18.2°
18.2°
/
/
17μm
3.1°
6.2°
6.5°
7.5°
12.4°
12.4°
19.8°
/
12μm
2.2°
4.4°
4.6°
5.3°
8.8°
8.8°
14.0°
/

Optical

Focal Length[mm]
50
F/#
1.2
Format
Φ21.8

Mechanical

Interface
Thread
Focus Mechanism
Fixed Athermalized
Dimensions [mm]
Φ49x55.6
Weight
<144g

Environmental

Operating Temperature
-40℃ to +80
External Coating
AR
Front Element Sealing
IP67
Download document
FAQ
- Why the lens autofocus is not clear?

There are many reasons why the lens autofocus is not clear, the main reasons are as follows which can be checked one by one:

1. During the focusing process, there is a large moving target in the lens screen (occupying more than 1/3 of the picture), can be refocused;

2.If the lens is used for a long time, the gear, CAM and other transmission parts wear and tear, resulting in unclear focus, the module or control board parameters can be adjusted to make the focus clear again;

3. Hardware problems, such as potentiometer does not work, replace the hardware that does not work.

- Why can not the lens control board or module connect to the computer?

There are many reasons why the lens control board and the computer cannot be connected, the main reasons are as follows which can be checked one by one:

1. Replace the USB port, which may be incompatible with the data cable;

2.Replace the data cable,maybe the data cable is not compatible with the computer or the cable data is wrongly selected;

3. Confirm the wiring of the module or the control board, maybe the wiring is loose;

4.Module or control board hardware problem, replace the hardware.

APPLICATIONS
Hand-held Thermal Imaging Devices
Homeland Security
Thermal Imaging Body Temperature Screening
Review
  • Loading...